EEBUS Devices
Regarding the use of the database, please note the following points. The EEBus Initiative e.V. only publishes data based on third-party test results. The purpose of the database is to provide an initial informative overview of which manufacturers have had their equipment tested for compatibility with the EEBUS standard. This does not imply that all listed devices are indeed compatible. Verification of individual compatibility cannot be substituted by the database.
| Manufacturer | Product | FW Version | SHIP / SPINE Version | Use Case | State | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| GCPH - Grid Connection Point Hub | ||||||||||
| Power Plus Communications AG | CLS Adapter Steuerung 2.0 | 2.3.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3 LPP v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3 MPC v1.0.0
Aktor: Monitoring Appliance
Szenario: 1, 2, 3, 4, 5 | pilot-qualified | |||||
| Theben Smart Energy GmbH | Mehrwertmodul / Controlmodule | 1.18.9 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3 MPC v1.0.0
Aktor: Monitoring Appliance
Szenario: 1, 2, 3, 4, 5 | pilot-qualified | |||||
| Theben Smart Energy GmbH | SELEXA D | 1.18.2 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3, 4 LPP v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| Prolan Zrt | Prolan Steuerbox | 0.7.2a | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3, 4 MPC v1.0.0
Aktor: Monitoring Appliance
Szenario: 1 | pilot-qualified | |||||
| VIVAVIS AG | STBF24C | 2.2-7 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3, 4 LPP v1.0.0
Aktor: Energy Guard
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| Submeter | ||||||||||
| TQ-Systems GmbH | EM420 Smart Meter (2. Gen) | 3.5.0 | 1.0.1 / 1.3.0 |
+
MPC v1.0.0
Aktor: Monitored Unit
Szenario: 1, 2, 3, 4, 5 | pilot-qualified | |||||
| EMS – Energy Management System | ||||||||||
| beegy Gmbh | beegyHEMS | 5.17 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| Consolinno Energy GmbH | Leaflet HEMS | 1.7.x | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3, 4 LPP v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 MPC v1.0.0
Aktor: Monitoring Appliance
Szenario: 1, 2, 4 | pilot-qualified | |||||
| eQ-3 AG | HmIP-HCU1(-A) | 1.3.0 (Plugin v1.1.4) | 1.0.1 / 1.3.0 |
+
MPC v1.0.0
Actor: Monitoring Appliance
Scenario: 1, 2 | pilot-qualified | |||||
| gridX GmbH | gridBox | XENON 2.3 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Actor: Energy Guard & Controllable System
Scenario: 1, 2, 3, 4 LPP v1.0.0
Actor: Energy Guard & Controllable System
Scenario: 1, 2, 3, 4 MPC v1.0.0
Actor: Monitoring Appliance
Scenario: 1, 2, 3, 4 | pilot-qualified | |||||
| Kiwigrid GmbH | Energy Manager VoyagerX, Energy Manager RailX | KiwiOS X Edge 10.25.8.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Actor: Energy Guard & Controllable System
Scenario: 1, 2, 3, 4 | pilot-qualified | |||||
| KOSTAL Solar Electric GmbH | KOSTAL Smart Energy Meter G2 | 2.7.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3 LPP v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| New Inergy GmbH - DaheimLaden.de | DaheimLaden LastManager | 1.2.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Actor: Controllable System
Scenario: 1, 2, 3 | pilot-qualified | |||||
| SMA Solar Technology AG | Sunny Home Manager 2.0 | 2.18.4.R | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3 LPP v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3 MPC v1.0.0
Aktor: Monitoring Appliance
Szenario: 1 | pilot-qualified | |||||
| SolarEdge Technologies Inc. | ONE Controller for Residential | 1.2.3 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 LPP v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| SolaX Power Network Technology (Zhejiang) Co.,Ltd | XHub | V004.01 | 1.01 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| SPiNE GmbH | Energy Link / SPiNE Application Platform | > v0.1.5 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 LPP v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| SpotmyEnergy GmbH | SmartRobo | SmartRobo Edge Interface v10.25.8.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Actor: Energy Guard & Controllable System
Scenario: 1, 2, 3, 4 | pilot-qualified | |||||
| #colspan# | ||||||||||
| Tibber (Kiwigrid GmbH) | Tibber link (Energy Manager VoyagerX) | KiwiOS X Edge 10.25.8.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| TQ-Systems GmbH | EM410 OEM-HEMS | 3.5.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3 LPP v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3, 4 MPC v1.0.0
Aktor: Monitoring Appliance
Szenario: 1, 2, 3, 4, 5 | pilot-qualified | |||||
| #colspan# | ||||||||||
| TQ-Systems GmbH | Charging Management DM100 | 3.19 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3 | pilot-qualified | |||||
| #colspan# | ||||||||||
| TQ-Systems GmbH | Charging Management DM200 | 1.0.0 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Energy Guard & Controllable System
Szenario: 1, 2, 3 MPC v1.0.0
Aktor: Monitored Unit
Szenario: 1, 2, 3, 4, 5 | pilot-qualified | |||||
| HVAC - Heating, Ventilation and Air Conditioning Systems | ||||||||||
| Airzone | AIDOO PRO WI-FI | 1.0 | 1.0.1 / 1.0.3 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 MPC v1.0.0
Aktor: Monitored Unit
Szenario: 1, 2, 3, 4, 5 | pilot-qualified | |||||
| Vaillant Group |
+
-
Gateways, Controls, Heat Pumps, Electrical Heat Generator... Gateways: myVAILLANT Connect VR940f; sensoNET VR921; VR920; MiGo Link SR940f; MiLink SR921 | see product | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3 MPC v1.0.0
Aktor: Monitored Unit
Szenario: 1 | pilot-qualified | |||||
| Wolf GmbH | Link Home / Link Pro | 5.00 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 MPC v1.0.0
Aktor: Monitored Unit
Szenario: 1 | pilot-qualified | |||||
| INV - Inverter | ||||||||||
| KOSTAL Solar Electric GmbH | PLENTICORE S/M/L G3 | 3.04.03 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 LPP v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| EVSE - Electro Vehicle Supply Equipment | ||||||||||
| Bender GmbH & Co. KG |
+
-
Bender Charge Controller, 2nd to 4th generation CC612, ICC1612, ICC1622, CC613, DCC613, ICC1314, ICC1324, ICC1624, HCC1xx1 | 5.34.1 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Aktor: Controllable System
Szenario: 1, 2, 3, 4 MPC v1.0.0
Aktor: Monitored Unit
Szenario: 1, 2, 3, 4 | pilot-qualified | |||||
| Wanbang Digital Energy Co. Ltd | Artemis AC Charger | >2.2.6 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Actor: Controllable System
Scenario: 1, 2, 3, 4 | pilot-qualified | |||||
| Wanbang Digital Energy Co. Ltd | Range Rover Home Charger, Jaguar Home Charger, Discovery Home Charger, Defender Home Charger | >2.2.6 | 1.0.1 / 1.3.0 |
+
LPC v1.0.0
Actor: Controllable System
Scenario: 1, 2, 3, 4 | pilot-qualified | |||||